KP1004B horizontal ion fan
Model:KP1004B
application area
Product overview
KP1004B horizontal ion fan is a static elimination device developed and produced by Kapal to eliminate static electricity on the surface of objects.
The KP1004B horizontal ion fan can generate a large amount of airflow with positive and negative charges, which can neutralize the charges on objects. When the surface of the object is negatively charged, it will attract the positive charge in the airflow. When the surface of the object is positively charged, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized and eliminated. purpose of static electricity.
The KP1004B horizontal ion fan is provided with wind power by a cross-flow fan, and the wind power can be adjusted within a wide range by the speed control switch.
KP1004B horizontal ion fan is widely used in pharmaceutical manufacturing and assembly, electronic production and packaging, LED assembly line, micrometer and other industries.
Product features
* Quickly eliminate static electricity.
* The ion airflow covers a large area.
* With ionization indicator.
* There is a special ion emission needle cleaner.
* Angle adjustable.
*If necessary, a cold air heating device can be installed.
* The fan has a good grounding protection function.
Technical parameter
Input voltage | 220V/50Hz or 110V/60Hz |
The output voltage | AC 5.6KV |
power | 50W(no heating) |
250W(heating) | |
Ion balance | ≤|±10V|(300mm from the test center in front of the fan) |
Power down time | ≤2S(300mm from the test center in front of the fan) |
effective coverage | 600×600mm |
Operating temperature | 0℃-50℃ |
Working humidity | <75% |
Air volume | 70-120CFM |
noise | 50-65dB |
Ozone concentration | ≤ 0.03 ppm (150mm from the front center of the air outlet) |
Gross weight | About 7.3kg |
Dimensions | 450mm(L)*210mm(W)*190mm(H)(With stand) |
390mm(L)*210mm(W)*115mm(H)(Without stand) | |
surface | electrostatic spraying |
Test result
Test Conditions | |||
Humidity: ≤60% Test voltage: 1KV-100V Ambient temperature: 22℃ | |||
distance | 300mm | 600mm | |
Neutralization time | just | 1.0s | 1.9s |
burden | 0.8s | 1.8s | |
residual voltage | just | +7v | +9v |
burden | -7v | -9v |
* The test results of the test instrument using ME268A electrostatic comprehensive tester shall prevail.
* Tested according to IEC-61340-5-1 A·6.