KP1003B ion air curtain machine
Model:KP1003B
application area
Product overview
KP1003B ion air curtain is a static elimination device developed and produced by Kapal Company to eliminate static electricity on the surface of objects.
The KP1003B ion air curtain can generate a large amount of airflow with positive and negative charges, which can neutralize the charges on objects. When the surface of the object is negatively charged, it will attract the positive charge in the airflow. When the surface of the object is positively charged, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized and eliminated. purpose of static electricity.
KP1003B ion air curtain machine is widely used in pharmaceutical manufacturing and assembly, electronic production and packaging, LED assembly line, semiconductor assembly production line and other industries.
Product features
* Quickly eliminate static electricity.
* The ion airflow covers a large area.
* With ionization indicator.
* There is a special ion emission needle cleaner.
* The use of hanging installation can save space.
* The air curtain has a good grounding protection function.
* The air curtain machine has infrared sensing function, it will automatically start when there is someone, and the delay closing time can be set independently according to the situation.
Technical parameter
Input voltage | 220V/50Hz or 110V/60Hz |
The output voltage | AC 5.6KV |
Ion balance | ≤|±50V|(300mm from the test center in front of the fan) |
Power down time | ≤3S(300mm from the test center in front of the fan) |
Operating temperature | 0℃-50℃ |
Working humidity | <75% |
Working humidity | 120-330CFM |
noise | 50-90dB |
Ozone concentration | ≤ 0.03 ppm (150mm from the front center of the air outlet) |
Dimensions | 600/900/1000/1200/1500/1800/2000mm(L)*220mm(W)*195mm(H) |
surface | electrostatic spraying |
Test result
Test Conditions | ||
Humidity: ≤60% Test voltage: 1KV-100V Ambient temperature: 22℃ | ||
distance | 300mm | |
Neutralization time | just | 1.0s |
burden | 1.3s | |
residual voltage | ≤±50V |
* The test results of the test instrument using ME268A electrostatic comprehensive tester shall prevail.
* Tested according to IEC-61340-5-1 A·6.
* Tested data may vary due to changes in ambient temperature and humidity.