KP3006B Ion Air Nozzle
Model:KP3006B
application area
Product overview
KP3006B ion air nozzle is a fixed static elimination device developed and produced by Kapal Company to eliminate static electricity on the surface of objects. Requires compressed air and high-voltage power supply.
The KP3006B ion air nozzle can generate a large amount of air flow with positive and negative charges, which is blown out at high speed by the compressed air, which can neutralize the charge on the object. When the surface of the object is negatively charged, it will attract the positive charge in the airflow. When the surface of the object is positively charged, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized and eliminated. purpose of static electricity.
KP3006B ion air nozzle is widely used in coating, optoelectronic, electronic production and packaging, printing, automation equipment and other industries.
Product features
* Neutralize static electricity quickly.
* The ion airflow covers a large area.
* Small size, easy to install.
* The air nozzle can be equipped with a foot switch to control the compressed gas for customers to choose.
* The coil can adjust the wind direction arbitrarily.
* The air nozzle has a good grounding protection function.
Technical parameter
Operating Voltage | AC 4.6KV |
working distance | 150-300mm |
Air supply connector | Ф8mm(Customized according to customer requirements) |
Ion balance | ≤|±50V|(300mm from the test center in front of the wind nozzle) |
Power down time | ≤1S(300mm from the test center in front of the wind nozzle) |
use medium | clean compressed air |
Operating temperature | 0℃-50℃ |
Working humidity | <75% |
High voltage wire length | 2.8M(Customized according to customer requirements) |
High voltage wire length | 0.3-0.8Mpa |
Air velocity | 3-10m/S |
noise | ≤65dB |
Ozone concentration | ≤ 0.03 ppm (150mm from the front center of the air outlet) |
Gross weight | About 0.8kg (including 3M high-voltage wires) |
Configure Power | KP4001A / KP4004A |
Test result
Test Conditions | ||
Humidity: ≤60% Test voltage: 1KV-100V Ambient temperature: 22℃ | ||
distance | 300mm | |
Neutralization time | just | 0.9s |
burden | 1.0s | |
residual voltage | ≤±50V |
* The test results of the test instrument using ME268A electrostatic comprehensive tester shall prevail.
* Tested according to IEC-61340-5-1 A·6.