KP5004A ionic aluminum rod
Model:
application area
Product overview
KP5004A ion aluminum rod is a static elimination device developed and produced by Kapal Company to eliminate static electricity on the surface of objects.
KP5004A ion aluminum rod is a kind of static elimination device commonly used to eliminate static electricity without compressed air. Need to match KP4003A high voltage power supply can be used. The length can be customized according to customer's requirements.
The KP5004A ion aluminum rod can generate a large amount of air flow with positive and negative charges, which can neutralize the charge on the object. When the surface of the object is negatively charged, it will attract the positive charge in the airflow. When the surface of the object is positively charged, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized and eliminated. purpose of static electricity.
KP5004A ionic aluminum rod is widely used in sheet material processing, slitting, coil material, textile, printing and other industries.
Product features
* Neutralize static electricity quickly.
* The housing is sturdy, easy to install, and made of aluminum.
* Applicable to various harsh working environments.
* Aluminum rods have good grounding protection.
Technical parameter
Operating Voltage | AC7.0KV |
working distance | 100mm |
Operating temperature | 0℃-50℃ |
Working humidity | <70% |
Ion balance | ≤|±100V|(100mm from the front test center of the aluminum rod) |
Power down time | ≤2S(100mm from the front test center of the aluminum rod) |
Rod length | 100-3000MM(Customized according to customer requirements) |
cross-sectional area | 14mm(W)* 17mm(H)* X(any length)mm |
Rod material | Aluminum |
High voltage wire length | 3M |
Test result
Test Conditions | ||
Humidity: ≤60% Test voltage: 1KV-100V Ambient temperature: 22℃ | ||
distance | 300mm | |
Neutralization time | just | 1.2s |
burden | 1.3s |
* The test results of the test instrument using ME268A electrostatic comprehensive tester shall prevail.
* Tested according to IEC-61340-5-1 A·6.
* Tested data may vary due to changes in ambient temperature and humidity.