KP5003A ion wind aluminum rod
Model:KP5003A
application area
Product overview
KP5003A ion wind aluminum rod is an antistatic device developed and produced by Kapal Company to eliminate static electricity on the surface of objects.
KP5003A ion wind aluminum rod is a kind of electrostatic removal device commonly used to eliminate electrostatic adsorption dust. It needs to be equipped with compressed air and KP4003A high-voltage power supply before it can be used. The length can be customized according to customer's requirements.
The KP5003A ion wind aluminum rod can generate a large amount of airflow with positive and negative charges, which can neutralize the charges on objects. When the surface of the object is negatively charged, it will attract the positive charge in the airflow. When the surface of the object is positively charged, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized and eliminated. purpose of static electricity.
KP5003A ion wind aluminum rod is widely used in sheet material processing, slitting, coil material, textile, printing and other industries.
Product features
* Neutralize static electricity quickly.
* The ion airflow covers a large area.
* The housing is sturdy, easy to install, and made of aluminum.
* Safe induction without electric shock.
* A regulator can be added to adjust the air pressure arbitrarily.
* The wind aluminum rod has good grounding protection.
Technical parameter
Operating Voltage | AC 7.0KV |
working distance | 100-300mm |
Operating temperature | 0℃-50℃ |
Working humidity | <70% |
use medium | clean compressed air |
Ion balance | ≤|±35V|(300mm from the front test center of the wind aluminum rod) |
Power down time | ≤2S(300mm from the front test center of the wind aluminum rod) |
Air supply connector | Ф8mm(Customized according to customer requirements) |
Rod length | 100-3000MM(Customized according to customer requirements) |
Pipe diameter | Ф30mm |
Rod material | Aluminum |
High voltage wire length | 3M |
compressed air pressure | 0.3-0.8Mpa |
Test result
Test Conditions | ||
Humidity: ≤60% Test voltage: 1KV-100V Ambient temperature: 22℃ | ||
distance | 300mm | |
Neutralization time | just | 1.0s |
burden | 1.1s |
* The test results of the test instrument using ME268A electrostatic comprehensive tester shall prevail.
* Tested according to IEC-61340-5-1 A·6.
* Tested data may vary due to changes in ambient temperature and humidity.